Motor Imagery dataset from Cho et al 2017
…1005 - **Hardware**: Biosemi ActiveTwo - **Software**: BCI2000 3.0.2 - **Reference**: CMS/DRL…
- Participants
- 52
- Citations
- 95
- Size
- 16.7 GB
- Version
- vv1.0.2
- Updated
- Sep 29, 2026
100 results for "BCI2000" · page 4 of 10 · ranked by relevance
…1005 - **Hardware**: Biosemi ActiveTwo - **Software**: BCI2000 3.0.2 - **Reference**: CMS/DRL…
This dataset contains simultaneous EEG and eye-tracking recordings from 21 healthy participants performing a matrix-based single-character-presentation BCI spelling task. Calibration and copy-spelling sessions include event markers for target and non-target stimuli. It supports research on multimodal sensor fusion for EEG-based brain-computer interface typing systems.
…OI2h - **Montage**: standard_1005 - **Software**: BCI2000 - **Sensor type**: EEG - **Line frequency**: 50…
EEG recordings from 12 healthy participants performing an offline 4-class code-modulated visual evoked potential (c-VEP) reactive BCI task. This subset contains the m-sequence condition at 40% amplitude depth, from a factorial study that compared burst and m-sequence codes at 100% and 40% modulation depth. The dataset supports evaluation of CNN-based decoding with minimal calibration data and of the visual comfort of reduced-intensity stimuli.
…Signals were acquired with the general-purpose BCI2000 software (same sources). The…
EEG recordings from two tetraplegic pilots of team Brain Tweakers (CNBI, EPFL) during longitudinal motor-imagery BCI training for the Cybathlon 2016 BCI race. The dataset contains 16-channel EEG from cue-based offline calibration runs with three classes (both hands, both feet, rest), recorded at 512 Hz. It was re-released in BIDS format from the original Zenodo deposit via MOABB.
EEG recordings from 12 healthy participants performing an offline 4-class reactive BCI task based on code-modulated visual evoked potentials (c-VEP). The dataset covers the 'Burst c-VEP' condition at 40% amplitude depth, in which short bursts of aperiodic flashes are presented at 2-4 flashes per second. It supports work on stimulus design, visual comfort, and CNN-based bitwise decoding with minimal calibration data.
This dataset contains 64-channel EEG recorded at 1000 Hz from 31 healthy participants performing a row/column P300 speller task with 4L and 5L grid sizes. Each participant completed three sessions. It is the P300 component of a multimodal eye-BCI collection that also includes eye-tracking and high-speed video for analyzing ocular activity across BCI paradigms. Events are annotated with HED tags as Target and NonTarget flashes.
This dataset contains EEG recordings from 13 healthy participants in Study I of the bigP3BCI collection. Participants used a P300-based speller with a 9x8 checkerboard character grid and a performance-based paradigm. Data were recorded from 16 channels at 256 Hz and are annotated with target and non-target stimulus events using HED. The dataset is a BIDS-formatted derivative of the PhysioNet bigP3BCI release, prepared for BCI benchmarking.
Three-class motor imagery EEG dataset (MI-B) from the BCI competition at the 2023 World Robot Contest (WRCC2023). It contains recordings from nine subjects, two of them stroke patients and seven healthy, performing cued imagery of left hand, right hand and feet movements (30 trials per class). Signals were recorded with a 59-channel Neuracle EEG system at 1000 Hz and re-released in BIDS format via MOABB.